DEPARTMENT CHARACTERISTICS

It will be delivered with Air Conditioning, Bathroom Furniture, Shower, Heater, Illuminated Mirrors, Tempered Glass Door, Stove, Extractor Fan, Double Sink with Mixer, and spaces for; Refrigerator, Microwave Oven, Lava Crockery, and Washing Center. Integrating an avant-garde design that will optimize the plumbing, electrical, voice, and data installations, the materials in walls, floors, and ceilings will be of high quality, safety, resistance, and durability, and the doors and closets will be high-end, and manufactured with resistant materials and details sophisticated, including different carpentry jobs.

With the advice and supervision of the Insurance Company, The Pierre & Diamonds will be designed and built with the highest standards of safety, quality, and resistance in its architecture, engineering and finishing elements, in addition to having an anti-crisis refuge area certified, guaranteeing maximum protection primarily against fires, hurricanes and earthquakes, which will additionally obtain the benefit of a lower cost of the corresponding insurance policy in addition to strictly complying with the guidelines for the construction and comprensive reconstruction of the coastal strip of the state of Guerrero stipulated in the Art. 7, 9, and 10 of decree CJ/1031/2023.

The conceptual security and protection measures that will
increase the integrity and reliability of the Diamonds, in the occurrence of any
possible natural event catastrophic or disaster strikes that may occur, are the following:

HURRICANES

  • Wind dissipation windows to reduce pressure on walls and doors.
  • Self-deploying metal curtains for windows and doors.
  • Double tempered glass reinforced with resin/silicone intermediate core certified for CAT 5 hurricane.
  • Exterior glass windows and doors made of thick-walled aluminum profile, anchored, sealed and cemented to floors, walls and slabs.
  • Anchors using screws and metal plugs for all furniture, both in common areas and in services that are outdoors.
  • Action protocol for assembly, disassembly and safeguard of furniture in common, service and recreation areas.
  • Municipal certified hurricane shelter for residents.

FLOOD

  • Deployable anti-flood barriers at all accesses to floors that are below normal ground level.
  • Non-return valves in drainage or drainage systems.
  • Electric and autonomous pumps connected to the drain or drainage.
  • Storm pits to buffer water volumes.
  • Retaining walls on the coastal strip to prevent landslides, loss of beach, slides or liquefaction of the land that causes damage to structures.

FIRE PROTECTIONS

Compliance with standards established by the National Fire Protection Association (NFPA):

  • Fire code.
  • Low, medium, and high expansion foams.
  • Upright and hose systems.
  • Fixed water spray systems.
  • Water and foam sprays, as appropriate.
  • Stationary pumps.
  • Water for the use of systems.
  • Systems maintenance.
  • Detection, alarm and human security codes.
  • Combustible gas detection and warning equipment.

EVACUATION, SECURITY AND PROTECTION

  • Electrical generation plants for electric backup of equipment, systems, and facilities for emergency situations.
  • Critical security systems, signaling, CCTV, surveillance, emergency, lighting, communication, alarms, barriers, connected to backup electrical generators.
  • Emergency evacuation protocol for residents and staff.
  • Seismic alarm.
  • Electrical contacts protected with ground fault.
  • Closed Circuit Television System (CCTV) with face ID detection and recognition software, and behavior evaluation through Artificial Intelligence.
  • Automatic closing seismic valves for protection of Natural Gas/LP Gas installations.

ADDITIONAL REGULATIONS

  • Project authorized by a Responsible Construction Director for all items and construction aspects.
  • Estricta supervisión de obra.
  • Programas de Mantenimiento Correctivo, Preventivo, Predictivo (incluyendo CAPEX y OPEX).
  • Hydraulic installation in accordance with the regulations of the National Water Commission.
  • Use and exploitation of LP Gas NOM-004-SEDG-2004.
  • Design and sanitary installations in accordance with the regulations of the Ministry of Energy.
  • Compliance with the standard for electrical installations.
  • Cumplimiento de la norma para para instalaciones de protección seguridad y SCI de la Secretaría del Trabajo y Previsión Social.
  • Compliance with the complementary technical standards for state construction of Guerrero.

The conceptual security and protection measures that will
increase the integrity and reliability of the Diamonds, in the occurrence of any
possible natural event catastrophic or disaster strikes that may occur, are the following:

HURRICANE
  • Wind dissipation windows to reduce pressure on walls and doors.
  • Self-deploying metal curtains for windows and doors.
  • Double tempered glass reinforced with resin/silicone intermediate core certified for CAT 5 hurricane.
  • Exterior glass windows and doors made of thick-walled aluminum profile, anchored, sealed and cemented to floors, walls and slabs.
  • Anchors using screws and metal plugs for all furniture, both in common areas and in services that are outdoors.
  • Action protocol for assembly, disassembly and safeguard of furniture in common, service and recreation areas.
  • Municipal certified hurricane shelter for residents.
FLOOD
  • Deployable anti-flood barriers at all accesses to floors that are below normal ground level.
  • Non-return valves in drainage or drainage systems.
  • Electric and autonomous pumps connected to the drain or drainage.
  • Storm pits to buffer water volumes.
  • Retaining walls on the coastal strip to prevent landslides, loss of beach, slides or liquefaction of the land that causes damage to structures.
FIRE PROTECTIONS

Compliance with standards established by the National Fire Protection Association (NFPA):

  • Fire code.
  • Low, medium, and high expansion foams.
  • Upright and hose systems.
  • Fixed water spray systems.
  • Water and foam sprays, as appropriate.
  • Stationary pumps.
  • Water for the use of systems.
  • Systems maintenance.
  • Códigos de detección, alarma y seguridad humana.
  • Combustible gas detection and warning equipment.
EVACUATION, SECURITY AND PROTECTION
  • Electrical generation plants for electric backup of equipment, systems, and facilities for emergency situations.
  • Critical security systems, signaling, CCTV, surveillance, emergency, lighting, communication, alarms, barriers, connected to backup electrical generators.
  • Emergency evacuation protocol for residents and staff.
  • Seismic alarm.
  • Electrical contacts protected with ground fault.
  • Closed Circuit Television System (CCTV) with face ID detection and recognition software, and behavior evaluation through Artificial Intelligence.
  • Automatic closing seismic valves for protection of Natural Gas/LP Gas installations.
ADDITIONAL REGULATIONS
  • Project authorized by a Responsible Construction Director for all items and construction aspects.
  • Strict construction supervision.
  • Corrective, Preventive, Predictive Maintenance Programs (including CAPEX and OPEX).
  • Hydraulic installation in accordance with the regulations of the National Water Commission.
  • Use and exploitation of LP Gas NOM-004-SEDG-2004.
  • Design and sanitary installations in accordance with the regulations of the Ministry of Energy.
  • Compliance with the standard for electrical installations.
  • Compliance with the standard for safety protection facilities and SCI of the Ministry of Labor and Social Welfare.
  • Compliance with the complementary technical standards for state construction of Guerrero.